FACE VENTILATION MEASUREMENT WITH SULFUR HEXAFLUORIDE (SF6) by Robert P. Vinson, Fred N. KissellI2 John C. LaScola,3 and Edward D. Thimons4 AB S TRACT The face ventilation measurement method developed by the Bureau of Mines

[email protected]
News Detail
  • Handling and Use of Sulfur Hexafluoride Gas

    A. Processing Cart - a gas-handling unit equipped with a vacuum pump, storage tank(s), and filtration equipment necessary to recycle SF 6 gas. 1. The storage tank(s) on these carts is either a large central reservoir or one or more DOT-approved cylinders. 2. Reservoir-equipped carts shall not be transported over public roadways if the gas

    Get Price
  • SF6 Gas Handling System - Kaji Tech

    3 SF6 Gas Handling System Model: KL50V-5.5OL-PⅡ Features: · An original oil-less compressor and oil-free vacuum pump for withdrawal are built-in. · Portable, compact light weight, and liquid SF6 storage type SF6 gas handling system.

    Get Price
  • SF6 and the Environment - US EPA

    ° CFR 49 restrictions/ASME storage tanks – Code of Federal Regulations DOT Standards 49 Section 173.115 (b) SF6 GAS TEAM SF6 and the Environment Author:

    Get Price
  • Portable SF transfer unit Model GTU-10

    portable service equipment series. Modules of the series: Portable vacuum pump, model GVP-10 Portable SF6 filter unit, model GPF-10 vacuum compressor, model GVC-10Portable SF6 transfer unit, model GTU-10Portable SF6 Portable SF6 gas cylinder scale, model GWS-10 The model GTU-10 is an instrument developed specifically for SF6 gas. Due to the

    Get Price
  • SF1 - SF2 - SF4 Skid -Tank-mounted SF6 - SF8 Twin SF6 - SF8

    Instruction book 2920 1521 00 10 1.4 Regulating system on SF Skid - Tank-mounted - Twin The air net pressure is kept within limits by a pressure switch mounted in the cabinet below the control

    Get Price
  • Solvay Special Chemicals

    Pressure in the SF6 tank as a function of temperature and density 26 Curves of pressure/temperature 27 and viscosity Curves of thermo conductivity 28 and heat transfer Optical properties 29 Chemical behaviour Behaviour at elevated temperatures 30 Behaviour under the influence of electrical discharges 30 Corrosion characteristics of SF6

    Get Price
  • SF Gas Handling 6 - eknis.net

    Mobile and portable versions Electronic weighing scales 0 –150 kg (option) Compact, mobile vacuum pumps for small compartments High-performance, mobile vacuum pumps for large switchgear compartments DILO Service Carts Mini-Serie For effi cient SF6 gas handling on small gas com- partments

    Get Price
  • Storage Tank for Gaseous or Liquid Storage of SF6 Gas with

    SF 6 gas storage tanks Safe storage. B176R.. These tanks offer sufficient volume to store or withdraw even large gas quantities in gaseous or liquid form. This series features a special feature: the entire gas content can be withdrawn at once without having to heat the tank.

    Get Price
  • NFPA 30-2008: Basic Requirements for Storage Tanks

    Feb 22, 2011 · fixed tanks exceeding 60 gal. (230L) portable tanks and IBC’S 793 gal. (3,000 L) portable tanks connected to fixed piping not used for processing Chapter 21 Chapter 21 –– GeneralGeneral basic design requirements tank can be of any shape, size or type must be constructed per recognized engineering standardsengineering standards

    Get Price
  • PATIENT/CAREGIVER INSTRUCTIONS Oxygen Cylinder and

    You should use your back-up/portable oxygen system while re˜lling and cleaning your humidi˜er bottle. Step 1: Remove the humidi˜er bottle from the concentrator. Step 2: Attach a nipple adapter to backup cylinder. Step 3: Remove the oxygen tubing from the humidi˜er bottle and attach it to the nipple adapter on your backup tank. Step 4: Open

    Get Price
  • SF6 properties, and use in MV and HV switchgear

    Cahier Technique Schneider Electric nO. 188 / p.3 SF6 properties, and use in MV and HV switchgear Contents 1 Introduction 1.1 A brief history of use of SF6 p.4 1.2 SF6 manufacture p.5

    Get Price
  • Catalog of Guidelines and Standards for the Handling and

    Portable GC Aug 1994 9 National Institute of Standards and Technology (NIST) Christophorou, L.G., Olthoff, J.K., and Green, D.S. Gases for Electrical Insulation and Arc Interruption: Possible Present and Future Alternatives to Pure SF 6 Nov 1997 9

    Get Price
  • SF Maintenance Equipment Fundamentals

    from the GIE to the storage tank. Depending on design, it may also be used to transfer gas from the storage tank back to the GIE. There are several compressor designs that are currently used: oil-based, oil-free, and oil-less. Among these are direct-drive, belt-driven, and pneumatic-driven units.

    Get Price
  • Sulfur Hexafluoride SF6 Safety Data Sheet SDS P4657

    Formula : SF6 1.2. Relevant identified uses of the substance or mixture and uses advised against Use of the substance/mixture : Industrial use. Use as directed. 1.3. Details of the supplier of the safety data sheet Praxair, Inc. 10 Riverview Drive Danbury, CT 06810-6268 - USA T 1-800-772-9247 (1-800-PRAXAIR) - F 1-716-879-2146 www.praxair 1.4.

    Get Price
  • Integrated Management for the Handling and Disposal of SF6 Gases

    Avoid SF6 gas emissions to the environment in the process of installing and removing the portable manometer performed monthly in 21 compartments of the substation Monitoring and early detection of SF6 gas leaks for corrective maintenance. We are currently aware of the leak when the low pressure alarm is emitted by the pressure gauge.

    Get Price
  • Oxygen Safety - Medical Necessities Services

    Oxygen tanks should be stored in a stand or cart to prevent tipping and falling. Store extra, unsecured tanks by placing them flat on the floor. Do not allow tanks to stand or lean in an upright position while unsecured. DO NOT store oxygen systems in unventilated areas such as closets or cabinets. NEVER drape clothing over oxygen systems.

    Get Price
  • Portable Oxygen Cylinders Training and Safety Guidelines

    Tank on/off valve Nipple Alignment peg adaptor Tube Oxygen tank (cylinder) Flow regulator knob T-handle How to use oxygen cylinders 1 Be sure the flow regulator knob is set at zero (see illustration 2). 2 Make sure the T-handle is tight. 3 Place the cylinder wrench on the cylinder’s on/off valve, located at the top of the cylinder.

    Get Price
  • White Papers | SF6 Gas Handling

    Sustainable SF 6 gas handling White Papers: SF 6 Nameplate Inaccuracies and their Impact on Greenhouse Gas Reporting. The consequences of incorrect nameplates on greenhouse gas reporting in the US are described in detail in the Whitepaper "SF 6 Nameplate Inaccuracies and their Impact on Greenhouse Gas Reporting":

    Get Price
  • FLAMMABLE AND COMBUSTIBLE LIQUIDS 29 CFR 1910

    29 CFR 1910.106 also requires portable tanks to have provision for emergency venting. Top-mounted emergency vents must be capable of limiting internal pressure under fire exposure conditions to 10 psig or 30 percent of the bursting pressure of the tank, whichever is greater. Portable tanks are also required to have at least one

    Get Price
  • Power Xpert XGIS gas-insulated medium-voltage switchgear

    the tank. A view port is also standard on each tank to verify position of the three position disconnect switch. An over pressure safety burst disc is integral to each tank located on the rear. The burst disc allows for the venting of arc gases should an arc event occur inside the tank. SF6 is used as the insulating medium inside the tank and allows

    Get Price
  • Storage of Flammable Combustible Liquids

    Feb 10, 2009 · Storage of Flammable and Combustible Liquids 29 CFR 1910.106 . The information in this presentation is provided voluntarily by the N.C. Department of Labor, Education Training and Technical\ഠAssistance Bureau as a public service and is made available in good faith.

    Get Price
  • 7 Types of Industrial Storage Tanks Explained - GSC Tanks

    Dec 25, 2018 · In Underground storage tank (UST), at least 10% of the tank’s stored volume is buried underground. Such tanks that are used for storing hazardous materials or fuels are regulated, and must have registration with the EPA. These tanks are suitable for people wanting to maximize the space and/or value of their property.

    Get Price
  • Oxygen Cylinder Hazard Summary - Veterans Affairs

    top and the co2 tank was a steel container that was similar in color to the o2 tank that was originally used for transport to the operating room. the gunmetal gray color of the co2 tank was significantly distored by rust. in addition, the co2 tank contained a standardized (dept of transportation) green label that reads "non-flammable".

    Get Price
  • Home Oxygen Safety Tips - ArmsCare

    Oxygen tanks should be stored in a stand or cart to prevent tipping and falling. Store extra, unsecured tanks by placing them flat on the floor. Do not allow tanks to stand or lean in an upright position while unsecured. • DO NOT store oxygen systems in unventilated areas such as closets or cabinets. NEVER drape clothing over oxygen systems. •

    Get Price
  • Portable leak detector - All industrial manufacturers - Videos

    The SF6 LEAKMATE leak detector is a great device for mobile SF6 leak detection. In practical use, it has a detection threshold of 1 x 10E-6 mbar l/s, which makes it perfectly In practical use, it has a detection threshold of 1 x 10E-6 mbar l/s, which makes it perfectly

    Get Price
  • Storage and Handling of Gas Cylinders Guidelines

    HRD-WHS-GUI-429.2 Storage and Handling of Gas Cylinders Guidelines 2015 December Page 1 of 14 Hardcopies of this document are considered uncontrolled.

    Get Price
  • 1 Face Ventilation ~easurkment With Sulfur

    FACE VENTILATION MEASUREMENT WITH SULFUR HEXAFLUORIDE (SF6) by Robert P. Vinson, Fred N. KissellI2 John C. LaScola,3 and Edward D. Thimons4 AB S TRACT The face ventilation measurement method developed by the Bureau of Mines

    Get Price
  • MODULE IV Secondary Containment, Oil Spill Control Spill

    Single walled 480 gallon lube oil tank inside a room with no drain. Concrete floor, 6” incline up to door. Containment capacity of the room should be calculated verified. It needs to hold 480 gallons. Room is 10’w x 14’l x 0.5’h = 70 ft 3 How to Prepare Your Own SPCC Plan: Module IV Secondary containment

    Get Price
  • Fuel Tank Emergency Procedure and SPCC Plan - Seton Hall

    2.4.1.12 Law School Building Emergency Generator tank: One 1000-gallon No. 2 diesel fuel AST tank located inside the Boiler Room on the lower level of the Law School building in Newark, NJ (indoors). 2.4.2 Secondary and tertiary Containment : All possible sources of major spills have spill-containment provisions, such as concrete pads and berms