News Center
where can I get SF6 decomposition detection system for gis

where can I get SF6 decomposition detection system for gis

Sep 30, 2020 · Gas detection is specifed for safe monitoring and measurement of SF6 levels on HV EHV Gas Insulated Switchgear (GIS) and Transformer rooms, 66kV-220kV. Detectors are located inside protected switchgear rooms to provide accurrate monitoring of gas concentrations – usually located in the local gas detection panel, fire protection system or control panel.

[email protected]
News Detail
  • SF6 Gas Detection For HV GIS Switchgear - Crowcon F-Gas Detector

    Sep 30, 2020 · Gas detection is specifed for safe monitoring and measurement of SF6 levels on HV EHV Gas Insulated Switchgear (GIS) and Transformer rooms, 66kV-220kV. Detectors are located inside protected switchgear rooms to provide accurrate monitoring of gas concentrations – usually located in the local gas detection panel, fire protection system or control panel.

    Get Price
  • SF6 Decomposition Content Analyzer Manufacturers , Suppliers

    LK406 SF 6 Decomposition SO 2,HF,H 2 S Content/ Purity /Moisture On line system is based on the current power system to further improve production safety requirements, provide decomposition products of SF 6 analysis of real-time monitoring of the design, development of intelligent online detection system for SF 6 equipment.

    Get Price
  • 973-SF6 Gas Analyzer | SF6 Humidity Purity Test |Testnordic

    973-SF6 gas analyser. SF6 Analyzers. SKU: N/A. The 973-SF 6 is an advanced SF 6 gas analyzer for the measurement of humidity, SF 6 purity and SO 2 concentration in SF 6 gas insulated switchgears (GIS) and other high voltage equipment. With its internal gas containment and recovery system, the 973-SF 6 provides a high quality and environmentally safe measurement solution within a single self-contained unit.

    Get Price
  • Detection of Partial Discharge in SF6 Decomposition Gas Based

    Jan 01, 2012 · Detecting and analyzing SF6 decomposition products under partial discharge (PD) is an effective way of diagnosing the internal operating status of gas insulated switchgear (GIS). In this text, three different gas sensors are developed, whose gas-sensing materials are pure MWNTs, MWNTs modified by mixed acid and NiCl2-doped MWNTs respectively.

    Get Price
  • GIS Insulation Fault Diagnosis Based on Detection of SF6

    Request PDF | GIS Insulation Fault Diagnosis Based on Detection of SF6 Decomposition Products | Partial discharge (PD) and partial over-thermal (POT) are the major failure modes of gas insulated

    Get Price
  • Research on the detection of SF6 decomposition products based

    Under partial discharge (PD), a gas-insulated switchgear (GIS) will produce SF6 decomposition products. If the concentrations of these products are higher than the standard values, this indicates that the GIS equipment is faulty. Photoacoustic spectroscopy techniques show a high sensitivity and good stabilit

    Get Price
  • ABB High Voltage Service Gas Management Solutions

    Decomposition Analysis with Leak Detection Using portable equipment, lab like results can be quickly and easily confirmed. Additionally, ABB offers decomposition analysis services and leak detection. If gas is able to leak out of a piece of equipment, then moisture and air can enter in it as well. - Market leading technology used to pin point leaks

    Get Price
  • (PDF) The SF6 Decomposition Mechanism: Background and

    This paper aims to explore the decomposition characteristics of SF6 under thermal fault, which can further improve the method of using SF6 decomposed components to diagnose inner insulation status

    Get Price
  • High sensitivity gas sensor to detect SF6 decomposition

    Oct 01, 2020 · Therefore, real-time monitoring of SF 6 decomposition products is essential for power system. At present, the traditional detection methods, including gas chromatography, mass spectrometry, infrared spectroscopy and metal oxides sensors, can no longer meet the needs of online monitoring for SF 6 decompositions because of their drawbacks of

    Get Price
  • Sulfur Hexafluoride SF6 Safety Data Sheet SDS P4657

    Sulfur hexafluoride Safety Data Sheet P-4657 This SDS conforms to U.S. Code of Federal Regulations 29 CFR 1910.1200, Hazard Communication. Date of issue: 01/01/1979 Revision date: 11/23/2016 Supersedes: 01/28/2015

    Get Price
  • Comparative Study of Materials to SF6 Decomposition

    Feb 07, 2017 · Available from: www.intechopen/books/nanomaterials-based-gas-sensors-for-sf6-decomposition-components-detection/comparative-study-of-materials-to-sf6-decomposition-components. Song Xiao, Xiaoxing Zhang, Ju Tang, Fuping Zeng, Cheng Pan and Yingang Gui (June 7th 2017).

    Get Price
  • HPFJ-311M SF6 Gas Decomposition Tester

    HPFJ-311M SF 6 Gas Decomposition Product Tester is a portable device designed to measure SF 6 gas decomposition product. The core component with electrochemical sensor from Membrapor to test SF 6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics.

    Get Price
  • Partial discharge recognition through an analysis of SF 6

    Feb 13, 2012 · Before recognizing PD types by analyzing SF6 decomposition products, the decomposition characteristics of SF 6 under different types of PD should be investigated first. In this paper, a gas chamber and four typical types of artificial defects were designed to simulate the SF 6 decomposition phenomenon under PD in GIS.

    Get Price
  • Online detection technology for SF 6 decomposition products

    The decomposition component analysis method can be used to monitor and diagnose the insulation state of SF6 electrical equipment in power industry. Here, the authors firstly compared the advantages and disadvantages of various SF6 decomposition products detection methods and analysed their feasibility of online monitoring.

    Get Price
  • EXPERT SYSTEM TO DIAGNOSE INCIPIENT FAUTLS IN GAS INDSULATED

    SF6 decomposition and its detecting tool designed. II. THE SF6 OPERATING ENVIRONMENT 2.1 Conditions for SF6 Decomposition In gas-insulated equipment, decomposition of SF6 by an electrical discharge is the most common mode of dissociation. The discharges can be broadly divided into three types according to the energy dissipated in

    Get Price
  • Development of a suitcase time‐of‐flight mass spectrometer

    Aug 18, 2016 · At present, many methods 1-10 have been used to detect the SF 6 decomposition components in GIS, for instance, gas chromatography (GC), 7-9 gas detection tube, 10 infrared absorption spectrometry, 1, 4-6 and metal oxide semiconductor gas sensor. 2, 3 Mass spectrometry has been regarded as an effective technique with the features of high sensitivity, high specificity, and rapid analysis speed. 11 Miniature or portable mass spectrometers are of growing interest due to their potential for in

    Get Price
  • The SF6 Decomposition Mechanism: Background and Significance

    Jan 24, 2017 · Gas Insulated Switchgear (GIS) has been widely used in substations. The insulating medium used in GIS is sulfur hexafluoride (SF6) gas. However, the internal insulation defect existed in GIS would inevitably lead to partial discharge (PD), and cause the composition of SF6 to SOF2, SO2F2 and SO2 and other characteristic component gases. The decomposition phenomenon would greatly reduce the

    Get Price
  • SGE-DOT Series Decomposition products detecting equipment

    Can be uploaded to a computer or printed directly. SF6 Decomposition Product Tester (Fault Location Analyzer) is a high-precision intelligent portable detector that can quickly detect the main decomposition products ( SO2, SOF2, H2S, CO) of SF6 gas in SF6 insulation equipment , such as SF6 circuit breakers, transformers, casings, GIS and transformers.

    Get Price
  • Multi - Functional Comprehensive Analysis SF6 Decomposition

    Multi - Functional Comprehensive Analysis SF6 Decomposition Analyzer Long Service Life. Product description This device can detect and judge the early faults of SF6 electrical equipment (circuit breaker, transformer, transformer, GIS and casing) quickly and quickly by monitoring two kinds of decomposition of SO2 and H2S at the same time.

    Get Price
  • Gas-Insulated Substations - GIS

    SF6 decomposes in the high temperature of an electric arc, but the decomposed gas recombines back into SF6 so well that it is not necessary to replenish the SF6 in GIS. There are some reactive decomposition byproducts formed because of the trace presence of moisture, air, and other contaminants. The quantities formed are very small.

    Get Price
  • Development of a suitcase time-of-flight mass spectrometer

    of the substation. The detection of SF 6 decomposition products can be used to diagnosis the condition of the GIS. METHODS:ThedecompositionproductsofSO 2,SO 2F 2,andSOF 2 wereselectedasindicatorsforthediagnosis.Asuitcase time-of-flight mass spectrometer (TOFMS) was designed to perform online GIS failure analysis. An RF VUV lamp was

    Get Price
  • What I have learned about SF gas testing….in 2015…a Practical

    (but also can be in deg C or deg C with ref to 20 deg C) 2. Purity expressed in % of SF 6 in the gas sample tested 3. Decomposition products, usually measure by SO2 detection Typical values for above are: 1. Moisture: <50 ppmv for new gas, <150ppmv for gas in use in a breaker or GIS and

    Get Price
  • Development of a suitcase time-of-flight mass spectrometer

    The detection of SF6 decomposition products can be used to diagnosis the condition of the GIS. METHODS: The decomposition products of SO2 , SO2 F2 , and SOF2 were selected as indicators for the diagnosis. A suitcase time-of-flight mass spectrometer (TOFMS) was designed to perform online GIS failure analysis.

    Get Price
  • Enhancement of Gas Sensing Characteristics of Multiwalled

    H<sub2</subS and SO<sub2</sub are important gas components of decomposed SF<sub6</sub of partial discharge generated by insulation defects in gas-insulated switchgear (GIS). Therefore, H<sub2</subS and SO<sub2</sub detection is important in the state evaluation and fault diagnosis of GIS. In this study, dielectric barrier discharge was used to generate CF<sub4</sub plasma and

    Get Price
  • [An ultraviolet spectroscopy method for rapid partial

    In this paper, firstly, the author reviewed the decomposition mechanism of SF6 under partial discharge, and then verified the rationality of detecting partial discharge by UV, and ultimately achieved the rapid detection of GIS partial discharge and fuzzy judgment of discharge time. PMID: 25881430 [PubMed] Publication Types: English Abstract

    Get Price
  • On-line Detection of GIS and Tank-type Circuit Breaker PD Defects

    The UHF signals generated by PD in the air are far less than SF6. In addition, it attenuates according to the distance. The metal coaxial structure of GIS can be seen as a good electromagnetic

    Get Price
  • Decomposition Characteristics of SF6 under Flashover

    In this paper, the flashover discharging experiment was carried out on epoxy resin surface in an SF6 atmosphere under pin-plate electrodes, with the electrodes distance from 5 mm to 9 mm. The concentration of seven characteristic gases was detected, indicating that the concentration of SOF2 and CF4 was the two highest, followed by SO2, CO2, SO2F2, CS2, and H2S. Based on the changes in the

    Get Price
  • First-principles study of Pd-MoSe2 as sensing material for

    SF 6 decomposition component detection is an effective way to diagnose the severity and type of electric discharge. In this study, MoSe 2 based material has been chosen as the gas sensing material for the detection of SOF 2 and SO 2 F 2 , the two characteristic decomposition components of SF 6 .

    Get Price
  • EPRI SF6 Research Past Highlights and Future Plans

    - The first is a portable SF6 (DPD) Decomposition Products Detector. The major application of the DPD is to provide a quick and accurate measurement of the sum of the dominant SF6 decomposition products. This instrument is portable, rugged and easy to operate and is able to handle sampling from energized equipment at system pressure.

    Get Price
edge-iconMaybe You Will Be Interested
toTop
Click avatar to contact us
Chat Online