  • Study on SF6 gas decomposition products of typical GIS defect

    Detection of SF6 gas decomposition products has been increasingly used for monitoring the insulation condition of Gas Insulated Substation (GIS) for its advantages, comparing to traditional

    Get Price
  • The SF6 Decomposition Mechanism: Background and Significance

    Jan 24, 2017 · 3. The detection methods of SF 6 decomposition components. So far, the main methods to detect the decomposition components of SF 6 in GIS are gas chromatography, infrared absorption spectroscopy, photoacoustic spectroscopy, and chemical gas sensor.

    Get Price
  • SF6 DIAGNOSTICS AND SOLUTIONS — Powertech Labs

    Sep 01, 2016 · Knowledge of the nature and relative amounts of SF 6 by-products can be used to determine the operating condition of the equipment, to locate faults, and to detect incipient faults in GIS. Powertech can also perform analysis on SF 6 gas for purity (including blend composition), decomposition products, and moisture. In addition, Powertech has the capability for complete on-site chemical analysis using a portable gas chromatograph and/or with Powertech’s decomposition products detector.

    Get Price
  • Detection of partial discharge in SF6 gas using a carbon NTs

    PD in GIS can lead to the generation of multiple decomposition products of SF6, and the detection and analysis of these decomposition products is important for fault diagnosis.

    Get Price
  • Byproducts of Sulfur Hexafluoride (SF6) Use in the Electric

    Detection Procedures and Guidelines SF 6 byproducts are difficult to detect chemically under normal working conditions. The presence of various SF 6 electrical discharge decomposition products and impurities (as well as the presence of SF 6 itself) makes measurement of the different byproducts problematic. A recent report in Transmission and

    Get Price
  • SF6 Gas Detection For HV GIS Switchgear - Crowcon F-Gas Detector

    Crowcon F-Gas SF6 Gas Detector. The Crowcon F-gas detector for sulphur hexafluoride (SF6) is ideal for GIS switchgear applications and is part of the Crowcon fixed gas detector range. Crowcon F-gas provides a lower total cost of ownership by providing fast, stable and dependable SF6 gas detection performance with infrared technology.

    Get Price
  • Detection of Partial Discharge in SF6 Decomposition Gas Based

    Jan 01, 2012 · The gas sensing response for SF6 PD decomposition products based on three MWNTs sensors is tested. The results show the mixed acid modifying could improve the sensitivity of MWNTs to detect SF6 PD decomposition products and the doping NiCl2 further improves the gas sensitivity of MWNTs, which makes MWNTs have better sensitivity and fast response characteristic.

    Get Price
  • ABB High Voltage Service Gas Management Solutions

    Decomposition Analysis with Leak Detection Using portable equipment, lab like results can be quickly and easily confirmed. Additionally, ABB offers decomposition analysis services and leak detection. If gas is able to leak out of a piece of equipment, then moisture and air can enter in it as well. - Market leading technology used to pin point leaks

    Get Price
  • Optical technology for detecting the decomposition products

    A detection tube can be used to detect major decomposition products, such as SO 2 or HF, at parts per million (ppm) levels. However, detection tubes have poor accuracy because the concentration of decomposition products is determined by color changes, making these tubes unsuitable for on-line monitoring. 21 A gas-sensitivity sensor can be

    Get Price
  • Development of SF6 decomposition gas sensor - ScienceDirect

    Jun 02, 2003 · This report has shown that the LaF 3 amperometric sensor can be successfully applied to detecting SF 6 decomposition gases. In order to improve the sensor sensitivity, the roughness of the electrode is an important factor. A sensor with the optimized electrodes can detect 0.2 vol. ppm of HF in 0.5 MPa SF 6.

    Get Price
  • A Review of Partial Discharges Measurement in GIS Systems Due

    This paper reviews the PD measurement techniques viz, chemical detection and acoustic detection used to detect SF6 decomposition in gas-insulated substations (GIS) due to PD phenomenon. Understanding the phenomenon and their detection techniques will be used to choose the most efficiency technique to detect the defects in GIS system

    Get Price
  • Do’s and Don’ts of SF6 Gas Handling

    May 28, 2014 · Do’s and Don’ts of SF6 Gas Handling Author: Jeff Spoljarick, Dave Smithberger Subject: how ComEd has had success in keeping low emissions rates, and the lessons they have learned; Jeff Spoljarick from ABB and Dave Smithberger from First Energy, presented on the best management practices of SF6 gas handling.

    Get Price
  • PAPER OPEN ACCESS 'HVLJQDQG'HYHORSPHQWRI N96) *DV,QVXODWHG*,6

    the partial discharge measurement and SF6 gas decomposition monitoring on GIS model test platform are discussed. Through design and development of 220kV SF6 gas insulated GIS type-test platform, the feasibility of the structure design of GIS bus and the solid insulation are

    Get Price
  • Development of a suitcase time‐of‐flight mass spectrometer

    Aug 18, 2016 · At present, many methods 1-10 have been used to detect the SF 6 decomposition components in GIS, for instance, gas chromatography (GC), 7-9 gas detection tube, 10 infrared absorption spectrometry, 1, 4-6 and metal oxide semiconductor gas sensor. 2, 3 Mass spectrometry has been regarded as an effective technique with the features of high sensitivity, high specificity, and rapid analysis speed. 11 Miniature or portable mass spectrometers are of growing interest due to their potential for in

    Get Price
  • Room temperature monitoring of SF6 decomposition byproduct

    To detect SF6 decomposition component at room temperature, use of SO2F2 still pose … Sulfuryl fluoride (SO2F2) is one of the ideal decomposition components of sulfur hexafluoride (SF6), which has been widely used as insulating and arc-quenching medium in gas-insulated switchgear (GIS) power equipment.

    Get Price
  • Partial discharge recognition through an analysis of SF 6

    Feb 13, 2012 · Before recognizing PD types by analyzing SF6 decomposition products, the decomposition characteristics of SF 6 under different types of PD should be investigated first. In this paper, a gas chamber and four typical types of artificial defects were designed to simulate the SF 6 decomposition phenomenon under PD in GIS.

    Get Price
  • Development of a suitcase time-of-flight mass spectrometer

    The detection of SF6 decomposition products can be used to diagnosis the condition of the GIS. METHODS: The decomposition products of SO2 , SO2 F2 , and SOF2 were selected as indicators for the diagnosis. A suitcase time-of-flight mass spectrometer (TOFMS) was designed to perform online GIS failure analysis.

    Get Price
  • Chemical Detection of SF6 Decomposition Products Generated by

    This paper describes application of carbon nanotube (CNT) gas sensor to chemical detection of sulfur hexafluoride (SF6) decomposition products generated by AC or DC corona discharge, aiming to develop a new diagnosis method of gas-insulated switchgear (GIS) filled with high pressure SF6 gas.

    Get Price
  • Gas-Insulated Substations - GIS

    SF6 decomposes in the high temperature of an electric arc, but the decomposed gas recombines back into SF6 so well that it is not necessary to replenish the SF6 in GIS. There are some reactive decomposition byproducts formed because of the trace presence of moisture, air, and other contaminants. The quantities formed are very small.

    Get Price
  • Health and environmental dangers of SF6-filled switchgear

    SF6 gas, used as a dielectric medium in circuit breakers and switchgear, has a global warming potential 24 000 times greater than CO2 and some of its by-products were used as chemical weapons in World War I. In life, in business, in the ordinary course of doing things, there is a certain level of risk […]

    Get Price
  • How to install SF6 400 KV Circuit Breaker 2014 - YouTube

    How to install SF6 400 KV Circuit Breaker 2014Installing Sulfur hexafluoride SF6 400kv circuit breaker in combine cycle power plant CCPP sub-station, in Dama...

    Get Price
  • The research of temperature properties of photoacoustic

    Photoacoustic (PA) spectroscopy technology has proved to be effective in detection of SF 6 decomposition products. But in the real application environment, the stability of the PA spectroscopy device is strongly affected by ambient temperature.

    Get Price
  • Comparative Study of Materials to SF6 Decomposition

    Feb 07, 2017 · To detect, evaluate, and diagnose the insulation status of SF 6 gas insulated equipment using the characteristics of SF 6 decomposition, a series of characteristic SF 6 decomposition components, SOF 2, SO 2 F 2, SO 2, H 2 S, CF 4, HF, and SF 6, are detected by gas sensors, including metal functionalized single wall carbon nanotubes (SWCNTs) [1–6], TiO 2 nanotubes [7–9], and graphene gas sensors [10, 11], as shown in Table 1.

    Get Price
  • Identification of DC corona generating SF6 decomposition

    AB - It is important to detect decomposition of insulating gas SF6 caused by partial discharges for gas-insulated switchgear (GIS). In the previous result, the author developed a novel partial discharges sensing using carbon nanotube (CNT) gas sensor.

    Get Price
  • SF6 gas handling - DILO

    Why is the SF 6 quality in the GIS circuit breaker of great importance?. The gas quality is the decisive factor for the correct and reliable function of the switchgear. Moisture or toxic and corrosive decomposition products in circuit breakers might have a negative impact on the insulation properties and switching ca

    Get Price
  • PAPER OPEN ACCESS 5HVHDUFKDQG'HYHORSPHQWRI1',56HQVRUDQG,WV

    1m light path, the detection limit of CF4 gas near 1312nm is less than 0.5ppm. The results of this study can provide an entirely new scheme for on-line monitoring of high-pressure open-light SF6 gas decomposition products, which can realize real-time on-line monitoring of the internal gas of the high voltage GIS equipment. 1. INTRODUCTION

    Get Price
  • [An ultraviolet spectroscopy method for rapid partial

    By selecting the appropriate wavelength range (295~305 nm), ultraviolet spectrum can identify SO2 from the complex by-products of SF6. In this paper, firstly, the author reviewed the decomposition mechanism of SF6 under partial discharge, and then verified the rationality of detecting partial discharge by UV, and ultimately achieved the rapid detection of GIS partial discharge and fuzzy judgment of discharge time.

    Get Price
  • SF6 Decomposition Reclamation

    SF6 Decomposition Reclamation. Abstract: The increasing application of SF6 as an insulating gas has led to many studies on SF6 decomposition in gas-insulated equipment. In the presence-of an electric arc, spark or corona, SF6 decomposes to a wide variety of chemically active products which possess completely different properties from SF6.

    Get Price
  • Development of a suitcase time-of-flight mass spectrometer

    6 gas-insulated GIS is of great interest. The detection of SF 6 decomposition products can be used to diagnose the degrees of arcing and prevent the unexpected failure of the electric equipment. At present, many methods[1–10] have been used to detect the SF 6 decomposition components in GIS, for instance, gas chromatography (GC),[7–9] gas