750kv-substation-onsite-service. On-site SF6 recovery service is driven by a trailer which equipped with our full set of recovery, refilling, purification equipment and measuring instrument, drive to the substandard gas compartment, perform onsite shutdown and maintenance, directly recover unqualified SF6 gas, recycle and purify them to be qualified and then return to gas compartment, the ...

[email protected]
News Detail
  • SF6, Sulfur Hexafluoride | Concorde Specialty Gases

    SF6, Sulfur Hexafluoride . Sulfur Hexafluoride (SF6) is an inorganic, colorless, odorless, and non-flammable gas. SF6 primary use is in the electrical industry as a gaseous dielectric medium for various voltage circuit breakers, switchgear and other electrical equipment, often replacing oil filled circuit breakers (OCBs) that can contain harmful PCBs.

    Get Price
  • SF6 Analyzer 973 - RH S

    Module When fitted, the SO 2 module is mounted to the back panel of the 973 which allows the SO 2 sen-sor to be easily replaced by the user. The sensor has to be replaced every two years. The cali-bration and replacement dates are indicated on the SO 2 Module. Gas Inlet Quick Coupling The sampling line is connected to the sample gas inlet.

    Get Price
  • Instrument User Manual V1 - Equipco: Rentals, Sales, Service

    SF6 P1 P1:p MANUAL Ion Science Ltd 10 of 15 Changing the sensor unit For changing the sensor unit, carry out the following Steps: • Power down the P2 (remove the fuse, observing the hints below) • Remove screws • Take off SmartSensor as indicated below • Pull the connector off the SmartSensor

    Get Price
  • SF6 Gas Services Management | Concorde Specialty Gases

    Until recently the management of SF6 gas was an activity that many organizations did not consider a core competence that can add value to their business. SF6 gas is a known necessity for a reliable and safe operation of equipment, but the management of SF6 is often considered an unwanted burden for many companies unless handled by a true

    Get Price
  • SF6 Gas Management Tracking | Concorde Specialty Gases

    CONCORDETRAK® can support the reporting and monitoring requirements of SF6 regulatory bodies making all reports accessible on-line 24 hours a day from any computer with no extra software needed. Toll Free: 1-800-818-5109 [email protected]

    Get Price
  • Gas Filling Equipment – SF6 Pressure Regulators | Concorde

    Concorde Specialty Gases offers high precision pressure regulators for SF6 gas. Our regulators control gas pressure for a lower, more consistent working pressure. Toll Free: 1-800-818-5109 [email protected]

    Get Price
  • Manual for installation and operation HB 605/04 en Use of SF

    Manual: Use of SF 6 insulating gas in ZX-switchgear HB 605 en - Revision 04 | 5 This manual serves as a supplement to the manuals for ZX0 block design, ZX1.2 and ZX2 switchgear. It contains safety and environ-mental topics concerning the insulating gas and describes the use of insulating gas and its handling. Fundamental notes on this manual

    Get Price
  • SF6 INSULATED METAL-ENCLOSED SWITCHGEARS

    Manual operating mechanisms (11) of the disconnectors, as well as of the earthing switches are fitted on the upper central panel (E2). CIRCUIT-BREAKER The metallic shielding of the SF6 circuit-breaker (5) is gas-tightly screwed on to its metal compartment (C).

    Get Price
  • Purchase SF6 Gas from Concorde Specialty Gases | Concorde

    Purchase SF6 Gas. Sulfur Hexafluoride (SF6) is an excellent gaseous dielectric for high voltage power applications. It has been used extensively in high voltage circuit breakers and other switchgears employed by the power industry. Applications for SF6 include gas insulated transmission lines and gas insulated power distributions.

    Get Price
  • Sf6 Gas Detection System

    750kv-substation-onsite-service. On-site SF6 recovery service is driven by a trailer which equipped with our full set of recovery, refilling, purification equipment and measuring instrument, drive to the substandard gas compartment, perform onsite shutdown and maintenance, directly recover unqualified SF6 gas, recycle and purify them to be qualified and then return to gas compartment, the

    Get Price
  • SF6 circuit breaker maintenance | TD Guardian Articles

    The first generation of SF6 circuit breakers was the lower voltage classes of 72kV and 145kV. As SF6 breaker technology improved, circuit breaker manufacturers introduced a dual pressure design for 145kV through 800kV applications, as well as air-blast breakers utilizing SF6 as the line-to ground dielectric insulation.

    Get Price
  • 973-SF Analyzer 6 - MBW Calibration AG

    MBW 973-SF6 Manual English V4.0 1 1. General This manual explains the function of the 973-SF 6 Analyzer with and without the SO 2 option. Throughout this manual the instrument will be called 973. Should the 973 be used in any other way than that described in this user’s manual, or outside the limits described, the built-in safety pro-

    Get Price
  • 973-SF Analyzer

    MBW973-SF6_MANUAL_E_V3.1 1 General This manual explains the function of the 973-SF 6 Analyzer with and without the SO 2 option. Throughout this manual the instrument will be called 973. This manual refers to instrument software versions 110525a and higher. Should the 973 be used in any other way than that described in this

    Get Price
  • Satellite XT Gas Detector with Interchangeable Sensors

    20408-0514 SF6 MST pyrolyzer module (sensor 9602-9710) - EN50270:2015 standard 4 weeks $1,469.82. 20408-0416 CH3F MST pyrolyzer module (sensor 9602-9720)

    Get Price
  • Manuals - Bacharach, Inc.

    3100 Instruction manual- remote sensor module without pump (EN) 3100 Instruction manual (EN) PGM-IR User Manual - SF6 (EN) PGM-IR Instructions - Battery Pack (EN)

    Get Price
  • CN101498754B - Method and device for judging SF6 electrical

    The digital signal processing device used for realizing the method comprises a signal conditioning module, a main control module and an output display module, can monitor the valuable state parameters of the SF6 gas, has the advantages of simple and reliable structure, little interference, good economical efficiency, high application value, and

    Get Price
  • Faulted SF6 Gas Circuit Breaker | Concorde Specialty Gases

    In the occurrence of arc discharges, spark discharges and corona discharges, SF6 can react with very little water, air, electrode and solid insulated material. Producing a byproduct include carbon tetrafluoride (CF4), thionyl sulfide (SOF2), sulfuryl fluoride (SO2F2), and sulfur dioxide (SO2), along with solid byproduct including aluminum fluoride, tungsten fluoride. Faulted SF6 gas is toxic […]

    Get Price
  • Utility Company Services for SF6 Gas | Concorde Specialty Gases

    Utility Company Services for SF6 Gas. Concorde Specialty Gases has over a decade of experience in working with utilities nationwide to provide SF6 gas and related services for their SF6 gas inventory and maintenance. Concorde’s fleet of appropriately equipped trucks will come on-site to help utilities: Recover gas from existing tanks or equipment

    Get Price
  • SF6.COM

    Toll Free: 1-800-818-5109 [email protected]degas. Home; SF6 Gas. SF6 Gas. SF6, Sulfur Hexafluoride; SF6 Safety Data Sheet; SF6 Gas Cylinder Specifications and SF6

    Get Price
  • ZX0.2 for OEM partners Gasinsulated medium voltage - ABB

    4 Gas density sensor and filling valve 5 Circuit-breaker 6 Current transformers 7 Cable connector on outer cone 8 Isolatable voltage transformers on the cable side 9 Heat sink 10 Solid-insulated busbars 11 Plug-in voltage transformers on the busbars Metal-enclosed As a further development of the tried and treated ZX0, ZX0.2

    Get Price
  • MBW 973-SF6 OPERATION MANUAL Pdf Download | ManualsLib

    Page 32 MBW973-SF6_MANUAL_E_V3.1... Page 33 Module The 973 internal SO module provides the user with the capability to measure SO concentra- tion in SF gas compartments. The module is conveniently mounted on the back panel of the instrument with the sample gas connections internally connected.

    Get Price
  • leak detection - cpsproductsonline

    Fully automatic electronic refrigerant leak detector for all HFC, HCFC, CFC, SF6 gasses blends. Exclusive POWERSHIFT software automatically monitors, controls adjusts all critical instrument settings to ensure maximum leak search results under any job environment.

    Get Price
  • Analyzer Calibration | Professional sensor calibration and

    Professional sensor calibration and module exchange Analyzers should be calibrated at least every two years to ensure zero emissions of SF 6 and accurate readings. The recommended calibration time of two years is based on average use.

    Get Price
  • Dräger Polytron® 7000 - Draeger

    With the Polytron 7000 remote sensor adaptor and lead it is possible to mount the sensor up to 30 metres from the polytron 7000 transmitter. This enables the user to read and operate the transmitter from a safe area, or detect toxic gasses and oxygen levels in difficult to reach areas, whilst still being able to view and configure the Polytron 7000 from a convenient location.

    Get Price
  • ION Science - Trusted manufacturer of gas detectors and gas

    Whether you are an original equipment manufacturer of portable, personal, or fixed industrial gas detection monitors, stack gas analyzers, or environmental monitoring instruments and require high quality, high-performance sensor, or work within an industrial working environment and need an instrument to detect or monitor hazardous gases to

    Get Price
  • F-Gas Detector Manual - Heat Tracing

    The connection of the internal IR sensor module to the interface electronics is via a 4 data cable (Fig. 4). The circuit board is screwed to the internal built outside. The IR gas sensor is integrated into this protect it from any unwanted external effects. Figure 4: 4-pin data Caution: The IR sensor module operated as a pair.

    Get Price
  • Midas: Can the Midas Gas Detector be used to detect Sulfur

    A suitable replacement to monitor for SF6 is the following: Satellite XT Satellite Transmitter (9602-0200) Extractive Module (20404-0300) Extractive Harness (9602.0014.10.00) Pyrolyzer Module for SF6 (20408-0114) Humidifier for Pyrolyzer (20408-4010) Moisture Exchanger for Humidifier (9604-4010) SF6 Sensor (9602-9710) IR-148 Infrared Gas Detector

    Get Price
  • X2GK - Compact Gas Analyzer - Emerson

    6 Pressure sensor is required 7 Limited to atmospheric if internal sample pump 8 Thermost. controlled sensor: 60 °C (140 °F) 9 For ranges 0–5…100 % and flow 0.5…1.5 l/min 10 Temperature variation: ≤ 10 K per hour 11 No sudden pressure surge allowed Oxygen sensors Paramagnetic (pO 2) Electrochemical (eO 2) Detection limit (4 σ) 1 4

    Get Price