Abstract. Sulfur hexafluoride (SF 6) is being widely used in a variety of industrial processes, commercial products and scientific fields due to its unique characteristics such as relatively low toxicity, extreme inertness and high dielectrics. However, the chemically stable gas is one of the most potent greenhouse gases (GHGs) that cause significantly global warming, and has been, thus, blanketed into the Kyoto Protocol.

[email protected]
News Detail
  • COLLISIONAL DECOMPOSITION OF SF6- - NIST

    unimolecular decomposition model originally proposed by Klots [5,6]. In this modeL the decomposition rates of SF 6-* for channels (1) [i = 1, 2, 3] may be expressed by k.(U~)-t 0 Pi _ (SF6 ). uj=u-Uo) h(2Jo+ l)Pvib (EVib) (3) x f ~;:duct(x)LJ LL (2J+l)dx,.x=o assuming that (SF6-)* and po lyatomic products of its decomposition can be treated as spherical tops.

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    Abstract. Sulfur hexafluoride (SF 6) is being widely used in a variety of industrial processes, commercial products and scientific fields due to its unique characteristics such as relatively low toxicity, extreme inertness and high dielectrics. However, the chemically stable gas is one of the most potent greenhouse gases (GHGs) that cause significantly global warming, and has been, thus, blanketed into the Kyoto Protocol.

    Get Price
  • The SF6 Decomposition Mechanism: Background and Significance

    Jan 24, 2017 · Although photoacoustic spectrum method, gas chromatography, infrared absorption spectroscopy, and gas sensors have been used for detecting SF 6 decomposition components at present, there is still lack of fast and low-cost online monitoring means to detect characteristic gases of SF 6 decomposition components in gas-insulated equipment.

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    Nov 01, 2007 · The compounds formed in the SF 6 decomposition may include S 2 OF 10, CF 4, COF 2, F 2, HF, H 2 S, NF 3, F 2 O, SiF 4, SO 2, S 2 F 10, SF 4, SO 2 F 2, SOF 2, SOF 4 and S 2 O 2 F 10, , , , , , , , , . Although the occupational exposure limit is not commonly used as a relative index of toxicity for chemicals, the information is the most common guideline useful for determining their safe levels in order to adopt adequate protection system and handling procedures.

    Get Price
  • Byproducts of Sulfur Hexafluoride (SF6) Use in the Electric

    the decomposition products and concentrations formed under actual conditions can vary depending on the equipment used and the type of electrical discharge (CIGRE 1997). 1 CIGRE (the International Council on Large Electric Systems) is a permanent non-governmental and non­ profit-making international association based in France.

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment - IEEE Journals

    SF6 Decomposition in Gas-Insulated Equipment Abstract: The increasing application of SF6 as an insulating gas has led to many studies on SF6 decomposition in gas-insulated equipment. In the presence-of an electric arc, spark or corona, SF6 decomposes to a wide variety of chemically active products which possess completely different properties from SF6.

    Get Price
  • Analysis of PD-generated SF6 decomposition gases adsorbed on

    A large number of studies indicated that SF 6 decomposes under PD through a series of chemical reactions where the low fluorinated sulfur species react with the trace H 2 O and O 2 in the gas...

    Get Price
  • Modeling of the relation between SF6 decomposition products

    Download Citation | Modeling of the relation between SF6 decomposition products and interior faults in gas insulated equipment | The method to measure SF6 decomposition products in gas insulated

    Get Price
  • Optical technology for detecting the decomposition products

    Optical detection is based on spectral analysis technology, which has been widely used in many fields, such as environmental science, medical treatment, chemical engineering, and food science. Most SF 6 decomposition products have absorption characteristics in both infrared (IR) and ultraviolet (UV) spectra. In different regions, the absorption

    Get Price
  • 34 Questions And Answers To Break the Myth About SF6 Gas In

    The decomposition products depend on the type of equipment and its service history; the quantities depend on energy (voltage, current, time) and the type of the equipment. 24. How hazardous are the decomposition products? See IEC 61634, Annex C: “Release of SF6 from switchgear and control gear – potential effects on health”.

    Get Price
  • SF6 Gas Discharge Decomposition Of Analyser Made in China

    SF6 Gas Discharge Decomposition Of Analyser. SF6 Gas Decomposition Tester uses the worldmost advanced UK Alpha high-performance, high resolution electrochemical sensors, embedded computer technology, is high-precision intelligent instrumentation. By detecting SF6 insulating material inside the device main cleavage product -SO2, the content of H2S, HF and CO , can quickly and accurately determine the early failure SF6 circuit breakers, transformers , GIS, busbars, bushings and transformers

    Get Price
  • China High Precision Sf6 Gas Discharge Decomposition Product

    Sf6 Gas Analyser, Sf6 Gas Discharge Decomposition Analyzer, Sf6 Analyzer manufacturer / supplier in China, offering High Precision Sf6 Gas Discharge Decomposition Product of Analyser Pricing, Low Price 100A Portable High Voltage Loop Contact Resistance Measurement, Huazheng Electric 30kv Ultra Low Frequency High Voltage Vlf Generator and so on.

    Get Price
  • A General Method of Decomposition Analysis*

    It is assumed that readers of this manuscript have already read HWP, which presents a new, general method (the line integral method) of decomposition analysis. Two application examples of the method (Example 1 and Example 3) are given in HWP. Additional two examples (Example 3 and Example 4) are shown in Sections 1 and 2 of this manuscript.

    Get Price
  • SF6 Gas Analysis - Qrometric

    MBW 973-SF6 gas analysers have been used for this application for almost 50 years and the 973-SF6 was the first instrument to include gas recovery as part of the measurement procedure. They continue to be the instrument of choice for the major switchgear manufacturers for SF6 gas analysis thanks to their precision, reliability and low maintenance cost.

    Get Price
  • Comparison of SF6 decomposition characteristics under

    Abstract: To investigate the difference between the sulfur hexafluoride (SF6) decomposition characteristics initiated by two sorts of insulation defects - free metal particles and metal protrusion defects - under negative DC partial discharge (PD), SF6 decomposition data was obtained under different DC voltages on the basis of constructing a SF6 decomposition experimental platform. The differences between the characteristic components and the characteristic ratios of the two defects at the

    Get Price
  • SF6 DIAGNOSTICS AND SOLUTIONS — Powertech Labs

    Sep 01, 2016 · Sulphur hexafluoride (SF 6) is a non-toxic, odourless gas with unique electrical properties. For over 50 years, it has been used in high-voltage gas-insulated switchgear (GIS), where its excellent dielectric and arc-quenching properties make it an ideal insulating gas for medium- and high-voltage equipment. However, when the gas decomposes, it forms decomposition products that are toxic to maintenance personnel and harmful to equipment.

    Get Price
  • Oem Voc Solution For Sale

    Welcome To Relations. SF6Relations (Henan) Co., Ltd. is a professional company focusing on research, production and sales of SF6 Tools, includ SF6 Monitoring Analysis equipment.SF6 Recyling Handling Equipment.SF6 On-site service and training.There is a place where you’ll get the Perfect SF6 solution for all your needs.

    Get Price
  • Implementation Of Treatment Recovery Of the SF6 Gas

    develop a new approach to treat SF 6 containing a high amount of decomposition products due to electrical normal interruption. AVANTEC has developed a SF 6 gas treatment technology, which aims at avoiding its destruction by a proper recycling of the polluted SF 6 gas, as it is described in this paper. A pilot installation was set,

    Get Price
  • Decomposition Characteristics of SF6 and Partial Discharge

    Tang et al. compared and analyzed the decomposition characteristics of SF6 under two types of common PDs [20], and recognized four typical PD types [21,22]. A large number of studies have shown that the type, concentration, and formation law of SF6 decomposed components are closely related to the type and severity of insulation faults in GIE.

    Get Price
  • Theoretical study of the decomposition mechanism of SF6/Cu

    Sep 10, 2018 · The compositions of SF 6 arc plasma are contaminated by Cu vapor through electrode erosion and thus affect the performance of the high-voltage SF 6 circuit breaker. But the essential data for chemical kinetic models to study the non-equilibrium compositions of SF 6 /Cu mixtures, namely the decomposition mechanism of SF 6 /Cu mixtures, is still not clear.

    Get Price
  • Collisional Decomposition of SF6 | NIST

    Sep 01, 2000 · Abstract. Insulating gas mixtures containing SF 6 have been promoted to serve as replacements for pure SF 6 in order to reduce SF 6 atmospheric emission. It has been argued that some synergism may be achieved by choosing proper buffer gases in mixtures with SF 6 such that the buffer gases efficiently slow down electrons into an energy range where the electron attachment cross section for SF 6 is large.

    Get Price
  • China SF6 Gas Analyzer Manufacturers, Suppliers, Factory

    SF6 synthesized tester integrates SF6 micro- water detector, SF6 purity tester, and SF6 decomposition analyzer as one. One time field measurement can complete the three detections, greatly save the gas in the device, which can save 2/3 of gas usage, while reduce the user's...

    Get Price
  • Decomposition Characteristics of SF6 under Flashover

    In this paper, the flashover discharging experiment was carried out on epoxy resin surface in an SF6 atmosphere under pin-plate electrodes, with the electrodes distance from 5 mm to 9 mm. The concentration of seven characteristic gases was detected, indicating that the concentration of SOF2 and CF4 was the two highest, followed by SO2, CO2, SO2F2, CS2, and H2S. Based on the changes in the

    Get Price
  • Multi - Functional Comprehensive Analysis SF6 Decomposition

    SF6 Decomposition Analyzer: Minimum Detection Amount: 0.1ppm: Repeatability: SO2, H2S ≤ 2%: Measurement Range: 0~100ppm (customizable) Temperature Humidity Range:-40℃ ~ +50℃, 95%RH Dimension: 252 X 310 X 98mm: High Light: sf6 gas leak detector, sf6 leak detection equipment

    Get Price
  • SF6 Gas Decomposition Tester Made in China - SF6 Gas

    SF6 Gas Discharge Decomposition Of Analyser. SF6 Gas Discharge Decomposition Of Analyser SF6 Gas Decomposition Tester uses the worldmost advanced UK Alpha high-performance, high resolution electrochemical sensors, embedded computer technology, is high-precision intelligent instrumentation. By detecting SF6 insulating...

    Get Price
  • First-principles study of Pd-MoSe2 as sensing material for

    SF 6 decomposition component detection is an effective way to diagnose the severity and type of electric discharge. In this study, MoSe 2 based material has been chosen as the gas sensing material for the detection of SOF 2 and SO 2 F 2, the two characteristic decomposition components of SF 6.

    Get Price
  • SF6 decomposition components under different metallic free

    The experiment was conducted on the SF 6 positive DC PD experimental system to determine the influence of the free‐conducting wire‐type particles of three kinds of metal materials (aluminum, 18/8 stainless steel, and copper) on SF 6 decomposition.

    Get Price
  • The Decomposition Products of Sulfur Hexafluoride (SF6) with

    to the environment or that is easier to dispose of has not yet been successful, the decomposition of sulfur hexafluoride remains a current field of research [4–6]. The activation of SF6 was first shown in the literature in 1900 by Moissan and Lebeau [7].

    Get Price
  • Comparative Study of Materials to SF6 Decomposition

    Feb 07, 2017 · In order to evaluate and diagnose the insulation status of SF 6 insulated equipment, gas sensor detection becomes an effective new method to realize the function by detecting the decomposition components of SF 6. Theoretical simulations are performed to understand the adsorption process of gas sensors and typical components of SF 6. And using carbon nanotubes (CNTs) based as novel kind of sensors show high sensitivity and quick responses to target gases.

    Get Price