750kv-substation-onsite-service. On-site SF6 recovery service is driven by a trailer which equipped with our full set of recovery, refilling, purification equipment and measuring instrument, drive to the substandard gas compartment, perform onsite shutdown and maintenance, directly recover unqualified SF6 gas, recycle and purify them to be qualified and then return to gas compartment, the ...

[email protected]
News Detail
  • Transorfilter

    pump used for air evacuation. This way mixture of SF6 and air is avoided. Particle filters in the filter unit filtrates the gas ac-cording to ISO 4406:1999, code 16/14/12. Chemical filter can be regenerated and dried out to remove moisture using the heater element in combination with the vacuum pump. Gas bottles for SF6 are not included with

    Get Price
  • Transorfilter

    Transorfilter, TFG FV-0016 Transorfilter TFG FV-0016 for evacuation of air and refilling of SF6 gas into gas insulated switchgear and circuit breakers. Technical data TFG FV-0016 Vacuum pump, (oil lubricated), pcs 1 Nominal flow rate vacuum pump, m3/h 16 Final pressure vacuum pump, mbar 0.5 Voltage and frequency, V, Hz* 3x400, 50

    Get Price
  • Transorfilter

    with the gas handling equipment. Transorfilter, Technical Data Measurements Compressor / Vacuum Unit Filter / Equipment Unit Length, mm: 800 800 Width, mm: 600 600 Height, mm: 410 410 Weight, kg: 73 43 Technical data Compressor / Vacuum Unit Filter / Equipment Unit Capacity oil-less SF 6 Compressor, m3/h: 1,2 - Capacity oil-free SF 6

    Get Price
  • FV0016 SF6 Gas Filling and Air Evacuation - Transorfilter Sweden

    FV0016 is a portable evacuation/filling equipment, designed and developed by Transorfilter Sweden, and is used when gas insulated switchgear and electric switches are to be air-evacuated and filled with SF6. The equipment consists of a trolley with a vacuum pump, gas regulator, carefully selected components for gas handling and separate hoses

    Get Price
  • SF Maintenance Equipment Fundamentals

    6 gas within insulated equipment (GIE) are reduced, a larger proportion of SF 6 inventories are distributed in smaller equipment. And, as larger, older equipment is replaced, many users are finding themselves with excess inventory of “used” SF 6. Fortunately, the technology used in the SF 6 maintenance equipment industry has advanced as well.

    Get Price
  • Gas handling SF6 - Transorfilter Sweden

    SF6 evacuation A hose is connected between portable FV1C equipment and gas-filled object via the supplied connection piece. Evacuation of SF6 takes place with the help of an oil-free compressor and dry running vacuum pump down to 1 mbar. Evacuated gas is stored in the customers gas bottle with a storage pressure of max 50 bar. Air evacuation

    Get Price
  • Gas handling SF6 - Transorfilter Sweden

    The equipment consists of three aluminum boxes that are connected with the supplied hoses before operation. A compressor box with 3 compressors, a vacuum box with 2 vacuum pumps (1 dry SF6 vacuum pump, 1 oil-lubricated air vacuum pump) and a filter box with 3 different filters and a control cabinet. SF6 evacuation

    Get Price
  • Gas handling SF6 - FV4C-A 4m3/h Gas - transorfilter.se

    Equipment FV4C-A for gas handling and gas recovery of SF6 gas is an automatic gas handling equipment. FV4C-A is designed with approved and well-tested components for SF6 gas. Leak-free couplings and components in FV4C-A for gas handling and gas recovery of SF6 are used to prevent emissions of SF6 gas.

    Get Price
  • SF6 air sensor Equipment | Environmental XPRT

    The SF6 Network Monitor is the central control unit from up to five SF6 Air Sensors to be connected. Warning and alarm thresholds can be set for each SF6 Air Sensor.The plug-and-play operating concept makes the handling very comfortable.

    Get Price
  • SF6 Transmitter - Draeger

    The infrared sensor measures SF6 in the ppm range so the transmitter can detect a leak in time. It also makes it easier for you to comply with occupational exposure limits. Connect the SF6 transmitter via an analogue or digital interface with a Dräger control unit to a gas warning system. This warns you early on exceeding the preset alarm values.

    Get Price
  • Medium voltage switchgear - Schneider Electric

    SF6 is used in electrical equipment because of its dielectric strength, excellent insulating properties and its arc-suppression capabilities. It insulates 2.5 times better than air (N2), so it allows very compact design Its quenching properties are 100 times better than air (N2) and has better heat dissipation than in air

    Get Price
  • User Manual SF6 GASCHECK 6000 EN - Precise Facilities

    area. In cases of very large leaks, blowing out the area with shop air often helps locate the exact position of the leak. 6. Following any service to the SF6 system, and any other service that disturbs the SF6 system, a leak test of the repair and of the service ports of the SF6 system should be done.

    Get Price
  • Oem Voc Solution For Sale - fdpbibis Webseite!

    750kv-substation-onsite-service. On-site SF6 recovery service is driven by a trailer which equipped with our full set of recovery, refilling, purification equipment and measuring instrument, drive to the substandard gas compartment, perform onsite shutdown and maintenance, directly recover unqualified SF6 gas, recycle and purify them to be qualified and then return to gas compartment, the

    Get Price
  • Transor Filter | Oil Filter Systems | One Micron Filtration

    Design and manufacturing of EDM and grinding oil filtration systems. Patented, self cleaning system filters to one micron. Grinding applications include carbide and tool steel.

    Get Price
  • solutions - Transor Filter

    It was then that Denic got in touch with Transor Filter (Elk Grove Village, IL). After hearing about the many bene-fits that Transor’s One Micron Filtration (OMF) had brought to other cutting tool manufacturers, Denic knew that this technology was what he needed in the new facility. As plans progressed for the new building, QCT, working in

    Get Price
  • Online Dew Point Monitoring of SF6-Gas-Insulated Equipment

    of an SF6-insulated switch in Finland (fall 2010). Figure 4. Measurement data (dew point, pressure, and temperature) from an indoor system. Installation of an Online Dew point Sensor When designing an online measurement setup for a dew point sensor in SF6-insulated equipment, the basic principles of water vapor behavior described earlier should

    Get Price
  • Transor Filter | PRODUCTS

    All units are equipped with chillers as standard equipment. Temperature control of oil to ± 0.1 °C Pre-filters for materials such as HSS and stainless can be built-in.

    Get Price
  • Oem Voc Solution For Sale - e-magic.be

    750kv-substation-onsite-service. On-site SF6 recovery service is driven by a trailer which equipped with our full set of recovery, refilling, purification equipment and measuring instrument, drive to the substandard gas compartment, perform onsite shutdown and maintenance, directly recover unqualified SF6 gas, recycle and purify them to be qualified and then return to gas compartment, the

    Get Price
  • Transor Filter | OMF TECHNOLOGY

    Rather than being replaced, the elements are cleaned automatically with compressed air that removes the debris and places it into a receptacle for reclamation or disposal (FIGURE 2). Life expectancy of the filter elements is approximately 25,000 hours, however, this figure is often times greatly exceeded.

    Get Price
  • Instrument User Manual V1

    To precisely determine SF6 concentration, SF6 AREACHECK P2 requires a reference value representing clean air. This reference value is taken and stored whenever the instrument is powered up or reset. You should therefore make sure that power up takes place under clean air conditions. ATTENTION: The fuse (T1A) is at mains voltage.

    Get Price
  • Medium-voltage product offer - Schneider Electric

    CBGS-0 SF6 circuit breaker switchgear Ratings/features • Up to 38 kV, 2,000 A, 31.5 kA, and 150 kV BIL • Compact design 24” W for mains/feeders and 48” W for tie • Fixed vacuum or SF6 circuit breaker • Solid insulated and shielded bus bar system • Internal arc tested 31.5 kA/1 s per IEC 62271-200

    Get Price
  • Transor Filter | CONTACT

    TRANSOR Filter USA. 515 Busse Road. Elk Grove Village, IL 60007, USA. Tel : +1-847-640 0273. Fax : +1-847-640 0793. E-mail : [email protected] www.transorfilter

    Get Price
  • Strategy for Elimination of SF6 in Production Processes

    Fully assembled leak check –will emit SF6 if leaks are present Reclaim into “shop” SF6 storage equipment Fill evacuated circuit breaker with the amount of “new” SF6 to be shipped inside the circuit breaker to user (largest units require site assembly and are shipped sealed with dry air –then evacuated and filled with new or

    Get Price
  • Instrument User Manual V1 - ION Science

    - Place the test specimen within the chamber free of SF6, close the chamber. - Zero the leak detector in clean ambient air by operating the “Zero” button. - For the initial measurement with the P1:p leak detector, push the sniffer probe for approximately 10 to 20 seconds through a corresponding connection directly into the chamber.

    Get Price
  • Industrial SF6 Gas Pressure and Measurement Products - WIKA USA

    SF 6 Gas Handling Equipment, Pressure Gauges, and Sensors . Sulfur hexafluoride (SF 6) is the insulator of choice for a variety of applications. Its electrical and thermal properties make it ideal for use in gas-insulated switchgear, breakers, and gas-insulated lines found in the transmission and distribution (TD) industry.

    Get Price
  • Transor Filter | APPLICATIONS

    Many Applications…One Solution . From a small chiller unit to multiple centralized systems, Transor creates the exact filtering solutions for your specific application.

    Get Price
  • Transor Filter | Oil Filter Systems | One Micron Filtration

    A New “Versatile” Option. The V is a complete central system that includes delivery pumps, refrigerant system and an automated sludge handling device for easy handling of debris sludge for reclamation or disposal.

    Get Price
  • Senja Leivo / Regional Segment Manager / Vaisala / Helsinki

    Sensor Installation The response time of dew point mea-surement in gas insulated equipment is not defined by the response time of the sensor itself, which is typically measured in seconds or minutes. The dominant factor is the system response after installation. When installing the sensor, some initial moisture from ambient air is

    Get Price
  • Study of fast transients generated in a GIS bus duct in

    5 bar for pure sF6, pure N2 and SF6-N2 mixtures with 5%, lo%, 15% and 20% SF6 content in N2 are shown in figure 2. Figure 3 shows the variations of the overvoltage factor with pressure for all the cases. The same data are shown in figure 4 as a function of %SF6 content in N2. A comparison of the VFTO levels of

    Get Price
  • Gashantering SF6 - FV1C-C 1m3/h - transorfilter.se

    FV1C-C utrustning för gashantering, gasåtervinning av SF6 gas. Mobil gasåtervinningsutrustning för SF6 gas. Evakuering av SF6 gas ner till 1 mbar.