smartGAS sf6 Treatment stationSF6 gas sensors for every application With the SF 6 sensors of the FLOW EVO series with measuring ranges of 100 Vol.-%, 2000 ppm, 1000 ppm and 50 ppm smartGAS offers technologies for monitoring SF 6 gas quality, SF 6 monitoring of room air and SF 6 leak detection.

[email protected]
News Detail
  • SF6 Sensors | Gas Insulated Switchgear (GIS) | smartGAS

    Non-dispersive infrared gas sensors (NDIR sensors) from smartGAS are ideal for measuring the SF 6 gas quality and for detecting even very small quantities of the harmful gas. Gas-insulated switchgears with high-voltage switches are used worldwide. The advantage over air-insulated switchgears is their compact design.

    Get Price
  • Accurate Multiple Gas Detection Module with NDIR - Electrical

    The SILAREX sensor platform from smartGAS detects multiple gases using NDIR (non-dispersive infrared absorption). SILAREX modules offer the selectivity, long-term stability and measuring accuracy of NDIR. The SILAREX solution allows multiple gases to be measured in the same module. It also has…

    Get Price
  • LMP91051 NDIR CO2 Gas Detection System - TI

    This Application Note begins with an introduction to nondispersive infrared (NDIR) gas sensing. The use of the LMP91051 NDIR AFE and MSP430F55XX microcontroller to make accurate CO2 NDIR gas measurements is examined. Performance, power, speed, and size are compared against the traditional discrete op amp system. 2 NDIR Gas Sensing Principle

    Get Price
  • smartGAS Mikrosensorik | smartGAS

    Then the NDIR gas sensors from smartGAS are the right choice: You receive high-quality optical components that enable good selectivity, low drift and very short reaction times. Our gas sensors also offer a number of advantages over conventional measuring systems. Learn more about the outstanding functions of our gas sensors.

    Get Price
  • smartGAS sf6 filled plants

    SF 6 insulation allows safe operation of high- and medium-voltage systems in close areas, since insulation with sulphur hexafluoride requires much smaller safety clearances. Non-dispersive infrared gas sensors (NDIR sensors) from smartGAS are ideal for measuring the SF 6 gas quality and for detecting even very small quantities of the harmful gas.

    Get Price
  • SF6 Transmitter - Draeger

    This increases the safety of your system, reduces the operating costs for SF6 and electrical energy as well as making a significant contribution to climate protection. Fast and reliable SF6 detection Equipped with non-dispersive infrared technology (NDIR), the SF6 transmitter detects sulfur hexafluoride quickly and reliably even in the ppm range in ambient air.

    Get Price
  • Our Products | Gas Sensors Detectors | smartGAS

    Gas sensors from smartGAS Blue Performance for gas sensor technology Our sensors are based on the non-dispersive infrared absorption of gases (NDIR technology). They fulfil the highest requirements in terms of accuracy, reliability and cost-effectiveness in process measurement and room air measurement.

    Get Price
  • C2H4 sensors | Ethylene Detection | smartGAS

    Wherever ethylene is to be found, the concentration of the gas plays an important role. The C 2 H 4 gas sensors of the FLOW EVO series from smartGAS safely and reliably detect the presence of ethylene in a measuring range from 0 to 2000 ppm. The sensors operate based on the principle of the non-dispersive infrared absorption of gases (NDIR technology).

    Get Price
  • Power Industry High Voltage Switchgear Vacuum Cham - SF6 Expert

    NDIR SF6 Sensor 10 years life for SF6 Gas Leakage detection.Measurement principle: Dual wavelength, Non Dispersive Infra-Red (NDIR).Measurement range: 0-50/1000/1500ppm.Gas supply: by diffusion (atmospheric pressure).Warm-up time: 2 minutes (start-up time).

    Get Price
  • Switchgear Temperature Monitoring - Hot-Spot Detection

    Fig. 4 Areas of interest for hot spot detection. Example of busbar joints in an air insulated switchgear . Detection Algorithm: State-of-the-art . Browsing through available hot spot detection systems on the market we discovered following repeating patterns of the temperature measurement evaluation:

    Get Price
  • Strategies for reliable arc flash detection in low-voltage

    Arc flash detection (AFD) systems have been applied in electrical equipment for over two decades [1]. Recently in the United States there has been increasing interest in utilizing AFD systems in low-voltage metal enclosed switchgear [2][3]. This increased interest in AFD systems is driven, at least in

    Get Price
  • Three-gas detection system with IR optical sensor based on

    Nov 01, 2015 · In this work, we display a compact three-gas detection system based on NDIR, herein, four single-channel pyroelectric sensors are integrated in the miniature optical gas chamber successfully. The novel gas chamber with two crossed elliptical surfaces is designed, which obtains a relatively long optical path and has a size of 10 mm (radius)×10 mm (height).

    Get Price
  • NDIR Gas Sensor Modules - Electrical Optical Components, Inc.

    The Functional Principle of Smartgas Sensors & ModulesGas Sensors For The Process Measuring TechnologyGas Sensors For Ambient Air MonitoringThe IR principle uses the individual absorption spectrum of the gas being measured. The exact gas concentration is determined through precise quantitative analysis of this spectrum. Because of this, their gas sensors function very selectively and are virtually unaffected by other environmental factors or gases. The functional principle of our gas sensors: long-term stability and performance thanks to NDIR technology from smartGAS As all measured gases absorb in varying spectral ranges, a kind of “fingerprint” arises that allows very selective characterization without cross-sensitivities. Gas sensors from smartGAS possess an integrated electronic evaluation system that displays a simple to use concentration signal to you as the user and reliably compensates for all drift and temperature influences.

    Get Price
  • High Accuracy NDIR Sulfur Hexafluoride SF6 Gas Leakage Detector

    China High Accuracy NDIR Sulfur Hexafluoride SF6 Gas Leakage Detector, Find details about China Gas Leakage Detector, Gas Leakage Detection from High Accuracy NDIR Sulfur Hexafluoride SF6 Gas Leakage Detector - HV Hipot Electric Co., Ltd.

    Get Price
  • SF6 Portable and Fixed Leak Detectors

    Transportable SF6 Leak Detection . Highly sensitive, detection guaranteed every time. SF6 LeakCheck P1:p is designed for the location, leak testing and measurement of SF 6 leaks in high voltage electrical switchgear. The revolutionary SF 6 leak detector rapidly detects leaks down to 1 x 10-8 ml/sec, with a response and clear down of less than 1 second.

    Get Price
  • Refrigeration air conditioning | smartGAS

    With the broadband refrigerant sensors, smartGAS offers a solution in which several gases can be measured in one hardware design. The broadband refrigerant sensors are factory calibrated to 2000 ppm R134a, but are also excellent for the measurement of R125, R404a, R407a, R410a R448a, R449a and R407f.

    Get Price
  • Effective and Safe Testing of GIS Switchgear - Electricity

    As the system does not need to be isolated, the measurement procedure is even less time consuming than testing a non-gas-insulated medium-voltage switchgear using the conventional measurement procedures. The VDS (Voltage Detection System) installed in the systems is used to measure the switching times.

    Get Price
  • NDIR Gas Sensors - Electrical Optical Components, Inc.

    The NBP filter turns the broadband detector into a very specific narrow band detector that looks at a specific IR band that the target gas absorbs. The NDIR system needs a broadband IR source. This source can be steady state for thermopiles, but needs to be pulsed for pyroelectric and lead selenide detectors.

    Get Price
  • SF6 Transmitter - Draeger

    This increases the safety of your system, reduces the operating costs for SF6 and electrical energy as well as making a significant contribution to climate protection. Fast and reliable SF6 detection Equipped with non-dispersive infrared technology (NDIR), the SF6 transmitter detects sulfur hexafluoride quickly and reliably even in the ppm

    Get Price
  • smartGAS detector equipments

    SmArtGas 4 : Gas Detector - Reliable gas detection in Ex zones. The SmArtGas 4 detector has been developed to replace our earlier Sigma SmArt and SmArtGas3 devices. SmArtGas 4 is based on a completely new electronic design. It has a new measuring head (either ‘FL’ or ‘FH’) which is the fruit of a three year development.

    Get Price
  • GAS SENSING SOLUTIONS - Leading Global Power Supply Manufacturer

    The trace gas detector Innova 1314i can be bundled with a multi-zone sampling systems with up to 24 channels. Refrigerant gas leak detection is becoming a high priority due to the risk to the environment, the increasing price of refriger-ant gas, and the high price for repair of major leaks. The need

    Get Price
  • Sf6 Gas Leakage Detector And Warning System For Sf6

    Sf6 Gas Leakage Detector And Warning System For Sf6 Switchgear Circuit Breaker Testing , Find Complete Details about Sf6 Gas Leakage Detector And Warning System For Sf6 Switchgear Circuit Breaker Testing,Sf6 Circuit Breaker Testing,Sf6 Gas Leakage Detector,Sf6 Gas Detector from Alarm Supplier or Manufacturer-Xuanzhaotong Electric Manufacturing (Baoding) Co., Ltd.

    Get Price
  • Gas Sensor Modules - Electrical Optical Components, Inc.

    High Performance NDIR Gas Sensor Modules smartGAS gas sensors use infra-red absorption of sg evo gases (NDIR technology) and thus are accurate, reliable and cost-efficient. They are suitable for an extremely wide variety of applications in process measuring technology and ambient air monitoring. Compact NDIR Gas Sensor Modules

    Get Price
  • SF Transmitter 6 High Voltage Technology - Dräger

    When insulating switchgear or transformers, sulfur hexafluoride (SF 6) is used. Since it is technically almost impossible to hermetically seal these systems, emissions can escape into the environment. Gas detection systems from Dräger make it possible to detect even the smallest leaks at an early stage and initiate corrective measures.

    Get Price
  • Three-gas detection system with IR optical sensor based on

    In this paper, a three-gas detection system with a environmental parameter compensation method is proposed based on Non-dispersive infra-red (NDIR) technique, which can be applied to detect multi-gas (methane, carbon dioxide and carbon monoxide). In this system, an IR source and four single-channel pyroelectric sensors are integrated in the miniature optical gas chamber successfully. Inner

    Get Price
  • Pest Control NDIR SO2F2 Gas Module - Electrical Optical

    The new SO 2 F 2 sensor from smartGAS has a measuring range of 4 Vol.-% and is particularly suitable for portable devices for container gassing. It is based on the technology of the FLOWEVO series, which is characterized by low detection limits, a compact design and fast response times.

    Get Price
  • Hybrid Metamaterial Absorber Platform for Sensing of CO2 Gas

    Sep 09, 2017 · level detection limit with high signal-to-noise ratio (S/N ratio). Therefore, present NDIR devices are bulky and limited for per-sonalized applications. Recently, 10 000 ppm detection limit is achieved in an NDIR setup with a 7.5 mm long optical interac≈ - tion length, where it also reports characterization of metamaterial emitter.[5]

    Get Price
  • smartGAS SF6 Equipment Repair equipments

    smartGAS SF6 Equipment Repair equipmentsThe SF6 transmitter is ideally suited for the gas measurement of sulfur hexafluoride in the field of high voltage engineering. The transmitter can be used both as a gas leak detector and to monitor the gas quality in gas-insulated switchgear (GIS) or transformers.

    Get Price
  • smartGAS sf6 Treatment station

    smartGAS sf6 Treatment stationSF6 gas sensors for every application With the SF 6 sensors of the FLOW EVO series with measuring ranges of 100 Vol.-%, 2000 ppm, 1000 ppm and 50 ppm smartGAS offers technologies for monitoring SF 6 gas quality, SF 6 monitoring of room air and SF 6 leak detection.

    Get Price