News Center
concordegas SF6 decomposition fittings for gis

concordegas SF6 decomposition fittings for gis

Deployment of the g3 gas mixture as a replacement for SF6 has taken a major step forward: the F35-145 kV gas-insulated substation (GIS) is now SF6-free too. It has the same physical footprint as its SF6-based GIS predecessor and can operate at ambient temperatures as low as -25 °C.

[email protected]
News Detail
  • SF6 Gas Specialty Gases

    Concorde Specialty Gases is the leading global supplier of Sulfur Hexafluoride gas (SF6 gas) and many other rare and specialty gases for industrial, commercial and consumer applications. We offer Sulfur Hexafluoride (SF6) and other specialty gases at the lowest prices possible. Concorde leads the industry with the highest quality gases, guaranteed to exceed industry standards.

    Get Price
  • SF6, Sulfur Hexafluoride | Concorde Specialty Gases

    SF6 gas under pressure is used as an insulator in gas insulated switchgear (GIS) because it has a much higher dielectric strength than air or dry nitrogen. This property makes it possible to significantly reduce the size of the electrical gear.

    Get Price
  • Handling and Use of Sulfur Hexafluoride Gas

    B. Decomposition Gasses and Solid By-Products When exposed to sustained or intense electrical arcs, SF 6 gas decomposes to form sulfur-fluoride gases and metal-fluorides which are toxic. If moisture is present, the decomposition by-products may also include sulfur-oxyfluorides and hydrofluoric and sulfuric acids.

    Get Price
  • (PDF) Mechanism of Formation of SF6 Decomposition Gas

    The SF6 is commonly used as an insulating gas in different applications; however the SF6 can be easily exploded into different decomposition gas products when subjected to electrical discharge

    Get Price
  • SF6 gas handling - DILO

    Why is the SF 6 quality in the GIS circuit breaker of great importance? The gas quality is the decisive factor for the correct and reliable function of the switchgear. Moisture or toxic and corrosive decomposition products in circuit breakers might have a negative impact on the insulation properties and switching capacity.

    Get Price
  • Gas-Insulated Substations - GIS

    A gas-insulated substation (GIS) uses a superior dielectric gas, SF6, at moderate pressure for phase-tophase and phase-to-ground insulation. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in SF6 gas inside grounded metal enclosures. The atmospheric air insulation used in a conventional, air-insulated substation (AIS) requires meters of air insulation to do what SF6 can do in centimeters.

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment - IEEE Journals

    SF6 Decomposition in Gas-Insulated Equipment Abstract: The increasing application of SF6 as an insulating gas has led to many studies on SF6 decomposition in gas-insulated equipment. In the presence-of an electric arc, spark or corona, SF6 decomposes to a wide variety of chemically active products which possess completely different properties from SF6.

    Get Price
  • ABB Library - All Categories

    Gas-insulated switchgear (GIS) has solved many problems by providing a far safer and more compact solution. The only significant drawback has been the use of SF6 gas, which requires very careful handling to avoid environmental issues. That drawback has been greatly reduced with AirPlus gas, now available in ABB GIS.

    Get Price
  • Mechanism of Formation of SF Decomposition Gas Products and

    reaction of decomposition products with water and oxygen are shown in Fig. 2. It can be seen that the major products of the decomposition reaction are sulphur oxides, while others are fluoride compounds. The concentrations of decomposition products are directly dependent on spark conditions and energy. Figure 2. The formation of SF 6

    Get Price
  • Gas Insulated Switchgear - GE Grid Solutions

    XD|GE provides Gas Insulated Switchgear (GIS) solutions for high to ultra . high-voltage power transmission and distribution networks. We offer a highly reliable, compact GIS that lowers installation space. and reduces maintenance requirements. Designed with light-weight, durable aluminum enclosures, total load on the foundation and building

    Get Price
  • SF6 Gas Services Management | Concorde Specialty Gases

    Concorde’s SF6 Gas Management Program We can help support you with all your SF6 gas needs and even offer suggestions to help you save time and money, all while maintaining on all environmental and regulatory matters. We guarantee that we can recycle your used or decommissioned gas to exceed industry standards ASTM- D2472 and IEC 376.

    Get Price
  • PAPER OPEN ACCESS 'HVLJQDQG'HYHORSPHQWRI N96) *DV,QVXODWHG*,6

    of characteristic parameters such as partial discharge and SF6 gas decomposition can be monitored periodically and quantitatively, the 220kV SF6 gas insulated GIS type test platform is designed and developed. The test platform is in accordance with GIS specifications used in

    Get Price
  • On-Site SF6 Services | Concorde Specialty Gases

    SF6 – On-Site Services It is for customers requiring SF6 gas services at their site. The Concorde Gas Advantage: No job too big, no job too small. Concorde’s trained and certified SF6 gas technicians will come to your site to remove your SF6 gas from: Gas Carts Electrical switches Transformers GIS system Accelerators Medical equipment

    Get Price
  • Typical Internal Defects of Gas-Insulated Switchgear and

    Dec 04, 2017 · Gas-insulated switchgear (GIS) is a common electrical equipment, which uses sulfur hexafluoride (SF6) as insulating medium instead of traditional air. It has good reliability and flexibility. However, GIS may have internal defects and partial discharge (PD) is then induced. PD will cause great harm to GIS and power system.

    Get Price
  • Guidelines – Sulphur Hexafluoride Management

    Compressed Gas Association (CGA). Gas cylinder fittings used for attachments to gas cylinder valves. These carry the association name e.g. CGA 590. DISS Diameter Index Safety System (DISS), high integrity fittings used for attachments to gas cylinders. Compared to CGA fittings, they are for higher purity and higher integrity applications. HF

    Get Price
  • CONSTRUCTION DESIGN FEATURES OF GAS INSULATED SYSTEM (GIS)

    Very fast transient over voltage (VFTO) is a unique electromagnetic transient phenomenon occurring in Gas Insulated Substation (GIS), which determines the insulation level of the GIS (above 330 kV).

    Get Price
  • Gas Insulated or Air Insulated Switchgear

    Various arguments exist around SF6 Gas Insulated (GIS) and Air Insulated (AIS) switchgear. Recently we had to change a GIS design to AIS due to an instruction from one of our clients. His concern is the global warming potential of SF6. While understanding the clients reasons, I'm not convinced on the argument.

    Get Price
  • Detection of Partial Discharge in SF6 Decomposition Gas Based

    Jan 01, 2012 · Detecting and analyzing SF6 decomposition products under partial discharge (PD) is an effective way of diagnosing the internal operating status of gas insulated switchgear (GIS). In this text, three different gas sensors are developed, whose gas-sensing materials are pure MWNTs, MWNTs modified by mixed acid and NiCl2-doped MWNTs respectively.

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    From the environmental and health points of view, it is necessary to mitigate and control the emissions of the decomposition products from SF 6 destruction processes because most of them (e.g. S 2 F 10, SF 4 and HF) are highly reactive, corrosive and toxic, and few of them are also potent GHGs. This article aimed to introduce the fully

    Get Price
  • Theoretical study of the decomposition mechanism of SF6/Cu

    Sep 10, 2018 · Besides, SF 6 decomposition products can be used to diagnose insulation faults of GIS and to evaluate the electric life of the SF 6 circuit breaker, but the uncertainty of the decomposition mechanism of SF 6 /Cu mixtures hinders the application of the analysis method of SF 6 decomposition products.

    Get Price
  • SF6 Experts – Supply, Service, Recycling | Concorde Specialty

    Manufacturer SF6 with a worldwide proven track record of customer satisfaction, excellence high SF6 gas purity. Let us manage your SF6 annual needs Toll Free: 1-800-818-5109 [email protected]

    Get Price
  • List of Global SF6 Gas Companies

    Shenzhen Xuming Electric Technology Co., Ltd. Power Transformer,11KV Transformer,33KV Transformer,20KV Transformer,15KV Transformer,10KV Transformer,Transformer Substation,Transformer,Dry Type Transformer,Oil Immersed Transformer,Fire Extinguishing Apparatus forTransformer,SF6 Gas-Insulated Metal-Enclosed Ring Main ….

    Get Price
  • NEC High Voltage Gas Insulated Switchgear Design Requirement

    GIS Switchgear Gas System. The insulating and interrupting medium shall be SF6 gas, conforming to IEC 60376 or ASTM D 2472. Assembly shall be divided into bays, and each bay into gas-tight and arc- resistant compartments, to confine the effect of any fault to the respective compartment. Minimum compartmentalization shall be as follows: a.

    Get Price
  • Minor inspection list for gas insulated switchgear GIS

    Mar 22, 2019 · For this, the corresponding equipment needs to be de energized. GIS manufacturers provide users with recommended maintenance plans which must be respected. Typical operations performed during this inspection are: Check of SF6 pressures (density). Check of SF6 density relay operations (including the wiring and alarms) Check of SF6 gas purity

    Get Price
  • Gas Monitor System, Compartments and Zones for GIS - An

    May 25, 2019 · Gas Monitor System: The insulating and interrupting capability of the SF6 gas depends on the density of the SF6 gas is at a minimum level established by design tests. The pressure of the SF6 gas varies with temperature, so a mechanical temperature-compensated pressure switch is used to monitor the equivalent of gas density. GIS is…

    Get Price
  • SF6 gas and SF6 gas quality | Frequently Asked Questions

    How is the concentration of decomposition products determined in practice? The SO 2 concentration is generally used as an indicator for the overall concentration of decomposition products (coefficient approx. 1:4), measured in ppm v.

    Get Price
  • News Room : GE Grid Solutions

    Deployment of the g3 gas mixture as a replacement for SF6 has taken a major step forward: the F35-145 kV gas-insulated substation (GIS) is now SF6-free too. It has the same physical footprint as its SF6-based GIS predecessor and can operate at ambient temperatures as low as -25 °C.

    Get Price
  • Protect, Preserve and Enhance

    SF6 decomposition products in the presence of an electrical discharge to form a variety of compounds which are extremely toxic and very difficult to measure. It is very important to measure the SF6 decomposition products and there are various IEC/CIGRE and ASTM methods which provide a guide to their use, handling and measurement.

    Get Price
  • Electric Transmission Distribution SF Coalition

    • SF6 sales and purchases. • SF6 sent off site for destruction. • SF6 sent off site for recycling. • SF6 returned to site after recycling. • SF6 stored in containers at the beginning and end of the year. • SF6 with or inside new equipment purchased during the year. • SF6 with or inside equipment sold to other entities.

    Get Price